8000 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer

This 8000 kva three-phase on-load tap changer (oltc) transformer is configured for a specific operating condition, application environment, or project requirement. It combines proven transformer platform design with targeted customization for winding material, environmental resistance, monitoring, voltage regulation, or special-duty performance according to export project needs.

The 8000 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer is a three-phase oil-immersed distribution transformer for step-down duty in utility networks, industrial plants and infrastructure projects. Capacity, voltage, vector group and impedance are confirmed against your network data, with the standard configuration shown in the technical parameters below.

Copper or aluminium windings, amorphous alloy cores and on-load tap changers are available where the project calls for them. Each unit is routine-tested in the factory and dispatched with test reports, and installation or commissioning support can be arranged for project deliveries.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity8000 kVA
High Voltage33 kV
Low Voltage0.4 kV / 0.415 kV / 0.433 kV / customized
Frequency50 Hz / 60 Hz
PhaseThree Phase
Cooling MethodONAN / ONAF optional
Vector GroupDyn11 / Yyn0 / YNd11 / customized
Tap ChangerOn-load tap changer (OLTC)
Tapping Range±8 x 1.25% / customized
Winding MaterialCopper / Aluminum
Core MaterialCRGO silicon steel
Insulation MediumMineral insulating oil
Tank TypeCorrugated tank / conservator tank optional
Impedance VoltageAccording to standard / customized
No-Load LossAccording to standard / customized
Load LossAccording to standard / customized
StandardIEC / customized project specification
InstallationOutdoor
ApplicationUtility distribution / industrial power / infrastructure projects

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Utility distribution networks
  • Industrial plants and workshops
  • Commercial buildings and mixed-use developments
  • Public infrastructure projects
  • Regional and municipal power distribution systems

Key Features

  • Designed for electrical control, automation, and load-side switching functions
  • Configurable internal component arrangement according to process and feeder requirements
  • Supports communication, metering, and interface options for smart plant integration
  • Cabinet construction suitable for industrial and infrastructure environments
  • Project-oriented documentation, labeling, and wiring scheme support available
  • Suitable for export supply and customized control-package delivery

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Frequently Asked Questions

Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 33 kV primary and 0.4 kV secondary and ONAN cooling.

Can you change the rating or voltage of this oil-immersed distribution transformer?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

Which standard applies to this oil-immersed distribution transformer, and is it certified?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

What cooling and protection are fitted?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

What information should we send for a quotation?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.


Typical Applications

The 8000 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer is specified in projects such as:

  • Utility and industrial distribution step-down duty
  • Solar and wind plant auxiliary and collector transformers
  • Infrastructure projects: rail, metro, airports, ports
  • Commercial and residential distribution substations
  • Outdoor pole, pad or kiosk mounted installations

Manufacturing & Factory Testing

Transformer manufacturing at our works, with quality control checkpoints through production and complete routine testing before dispatch:

  • Core cutting and winding with controlled process parameters
  • Vacuum drying and oil filling (oil types) or epoxy casting (dry types)
  • Routine tests: winding resistance, ratio and polarity, no-load and load loss, applied and induced voltage
  • Type test certificates from accredited laboratories available on request

Technical Drawing

Transformer Construction Overview Diagram - technical drawing for transformer
Transformer construction overview (illustrative). Final drawings are issued per order.

Delivery, Warranty & OEM Support

  • Typical lead time: 30 days from order confirmation for standard ratings; custom configurations are confirmed at order stage
  • Warranty: 2 years, with technical support available throughout the service life
  • OEM / ODM supported: private labelling, nameplate language and document packages
  • Seaworthy export packing; documentation set includes routine test reports, installation manuals and general arrangement drawings

Need a quotation for the 8000 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer? Send your single line diagram and ratings to our sales team and our engineers will confirm the configuration, lead time and price.

Frequently Asked Questions

Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 33 kV primary and 0.4 kV secondary and ONAN cooling.

Can you change the rating or voltage of this oil-immersed distribution transformer?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

Which standard applies to this oil-immersed distribution transformer, and is it certified?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

What cooling and protection are fitted?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

What information should we send for a quotation?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.

Application

Rated Capacity

Voltage Class

Environment

Reviews

There are no reviews yet.

Be the first to review “8000 kVA 33kV Three-Phase On-Load Tap Changer (OLTC) Transformer”