200 kVA 11kV S13 Three-Phase Oil-Immersed Distribution Transformer

This 200 kVA oil-immersed distribution transformer is designed for dependable power distribution in utility, industrial, and commercial networks. It provides stable electrical performance, practical oil-based cooling, and flexible configuration options for export projects requiring reliable outdoor service and configurable voltage ratios.

The 200 kVA 11kV S13 Three-Phase Oil-Immersed Distribution Transformer is a three-phase oil-immersed distribution transformer for step-down duty in utility networks, industrial plants and infrastructure projects. Capacity, voltage, vector group and impedance are confirmed against your network data, with the standard configuration shown in the technical parameters below.

Copper or aluminium windings, amorphous alloy cores and on-load tap changers are available where the project calls for them. Each unit is routine-tested in the factory and dispatched with test reports, and installation or commissioning support can be arranged for project deliveries.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity200 kVA
Primary Voltage (U1)11,000 V (11 kV)
Secondary Voltage (U2)415 V / 240 V (3-Phase 4-Wire)
Vector GroupDyn11
Rated Frequency50 Hz
Cooling MethodONAN (Oil Natural Air Natural)
Primary Current (I1)3.5 A
Secondary Current (I2)278.3 A
Guaranteed No-Load Loss (P0)340 W
Guaranteed Load Loss (Pk at 75°C)2300 W
Short-Circuit Impedance (Uk)4.0%
HV Insulation LevelLI 75 / AC 35 (11kV Class)
Temperature Rise LimitsTop Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight480 kg
Insulating Oil Weight320 kg
Total Assembled Weight950 kg
Overall Footprint (L×W×H)1150 mm × 800 mm × 1350 mm
Governing StandardsIEC 60076, BS 171, SON NIS, NERC Code

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Utility distribution networks
  • Industrial plants and workshops
  • Commercial buildings and mixed-use developments
  • Public infrastructure projects
  • Regional and municipal power distribution systems

Key Features

  • 200 kVA rated capacity for distribution network and industrial feeder applications
  • class design suitable for utility and regional power distribution systems
  • Oil-immersed structure for stable thermal performance and dependable outdoor operation
  • Available with copper or aluminum windings according to project and budget requirements
  • Supports IEC-based specifications and project-oriented voltage configuration
  • Configured for long service life, practical maintenance, and export project supply

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Frequently Asked Questions

What applications does the 200 kVA Oil-Immersed Distribution Transformer suit?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 11 kV primary and 415 V secondary and ONAN cooling.

Is 200 kVA Oil-Immersed Distribution Transformer the only rating you can build?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

How do you confirm the standard for a oil-immersed distribution transformer?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

Does it need a special room or foundation?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

How do we start an enquiry for a oil-immersed distribution transformer?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.


Typical Applications

The 200 kVA 11kV S13 Three-Phase Oil-Immersed Distribution Transformer is specified in projects such as:

  • Utility and industrial distribution step-down duty
  • Solar and wind plant auxiliary and collector transformers
  • Infrastructure projects: rail, metro, airports, ports
  • Commercial and residential distribution substations
  • Outdoor pole, pad or kiosk mounted installations

Manufacturing & Factory Testing

Transformer manufacturing at our works, with quality control checkpoints through production and complete routine testing before dispatch:

  • Core cutting and winding with controlled process parameters
  • Vacuum drying and oil filling (oil types) or epoxy casting (dry types)
  • Routine tests: winding resistance, ratio and polarity, no-load and load loss, applied and induced voltage
  • Type test certificates from accredited laboratories available on request

Technical Drawing

Transformer Construction Overview Diagram - technical drawing for transformer
Transformer construction overview (illustrative). Final drawings are issued per order.

Delivery, Warranty & OEM Support

  • Typical lead time: 30 days from order confirmation for standard ratings; custom configurations are confirmed at order stage
  • Warranty: 2 years, with technical support available throughout the service life
  • OEM / ODM supported: private labelling, nameplate language and document packages
  • Seaworthy export packing; documentation set includes routine test reports, installation manuals and general arrangement drawings

Need a quotation for the 200 kVA 11kV S13 Three-Phase Oil-Immersed Distribution Transformer? Send your single line diagram and ratings to our sales team and our engineers will confirm the configuration, lead time and price.

Frequently Asked Questions

What applications does the 200 kVA Oil-Immersed Distribution Transformer suit?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 11 kV primary and 415 V secondary and ONAN cooling.

Is 200 kVA Oil-Immersed Distribution Transformer the only rating you can build?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

How do you confirm the standard for a oil-immersed distribution transformer?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

Does it need a special room or foundation?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

How do we start an enquiry for a oil-immersed distribution transformer?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.

Application

Rated Capacity

Voltage Class

Environment

Reviews

There are no reviews yet.

Be the first to review “200 kVA 11kV S13 Three-Phase Oil-Immersed Distribution Transformer”

Your email address will not be published. Required fields are marked *

📋 Request a Quote

Request a Quote

Fill in your details and our engineers will contact you within 24 hours

Prefer to contact us directly?

Email: info@xsdfftransformer.com | Phone: +86 158 6789 7761 | WhatsApp: +852 2416 2620

Scroll to Top