8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer

This 8000 kva 1.0/ three-phase renewable power transformer is designed for renewable energy interconnection, step-up duty, and grid-side distribution applications. It supports stable operation in solar, wind, photovoltaic, and energy-storage projects where flexible voltage ratios, reliable cooling, and project-oriented outdoor design are required.

The 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer is a three-phase power transformer for substation, heavy industrial and utility duty where capacity and network conditions are specified more closely than for standard distribution units. Ratings are configured per the technical parameters below and confirmed against your system data.

Cooling method, vector group, impedance and tap range are engineered against your load profile and network parameters. Each unit is routine-tested before dispatch, and engineering support is available from enquiry through to commissioning.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity8000 kVA
High Voltage35 kV
Low Voltage1 kV
Frequency50 Hz / 60 Hz
PhaseThree Phase
Cooling MethodONAN / ONAF optional
Vector GroupYNd11 / Dyn11 / Yyn0 / customized
Tap ChangerOff-circuit tap changer / on-load tap changer optional
Tapping Range±2 x 2.5% / ±5% / customized
Winding MaterialCopper / Aluminum
Core MaterialCRGO silicon steel
Insulation MediumMineral insulating oil
Tank TypeConservator tank / sealed tank optional
AccessoriesBuchholz relay, oil level gauge, thermometer, pressure relief device, valves
Impedance VoltageAccording to standard / customized
No-Load LossAccording to standard / customized
Load LossAccording to standard / customized
StandardIEC / customized project specification
InstallationOutdoor
ApplicationUtility substations / industrial plants / infrastructure and regional power systems

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Solar power plants
  • Wind farm collector and grid interface systems
  • Photovoltaic station and inverter interconnection projects
  • Battery energy storage systems (BESS)
  • Renewable energy substations and export EPC projects

Key Features

  • 8000 kVA rated capacity for renewable interconnection, step-up, or project-side power conversion
  • Designed for solar, wind, PV, or energy-storage power system applications
  • Configurable voltage ratio for inverter-side, collector-side, or grid-side connection
  • Oil-immersed construction for dependable cooling in outdoor renewable projects
  • Project-oriented accessory and monitoring options available
  • Suitable for IEC-based renewable projects and export EPC supply

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Frequently Asked Questions

Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 0.35 kV primary and 1 kV secondary and ONAN cooling.

Can you change the rating or voltage of this oil-immersed distribution transformer?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

Which standard applies to this oil-immersed distribution transformer, and is it certified?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

What cooling and protection are fitted?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

What information should we send for a quotation?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.


Typical Applications

The 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer is specified in projects such as:

  • Substation step-up and step-down duty
  • Heavy industrial process power supply
  • Generator step-up for small plant and embedded generation
  • Grid interconnection where impedances are specified

Manufacturing & Factory Testing

Transformer manufacturing at our works, with quality control checkpoints through production and complete routine testing before dispatch:

  • Core cutting and winding with controlled process parameters
  • Vacuum drying and oil filling (oil types) or epoxy casting (dry types)
  • Routine tests: winding resistance, ratio and polarity, no-load and load loss, applied and induced voltage
  • Type test certificates from accredited laboratories available on request

Technical Drawing

Transformer Construction Overview Diagram - technical drawing for transformer
Transformer construction overview (illustrative). Final drawings are issued per order.

Delivery, Warranty & OEM Support

  • Typical lead time: 30 days from order confirmation for standard ratings; custom configurations are confirmed at order stage
  • Warranty: 2 years, with technical support available throughout the service life
  • OEM / ODM supported: private labelling, nameplate language and document packages
  • Seaworthy export packing; documentation set includes routine test reports, installation manuals and general arrangement drawings

Need a quotation for the 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer? Send your single line diagram and ratings to our sales team and our engineers will confirm the configuration, lead time and price.

Frequently Asked Questions

Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?

It is built for utility, industrial and commercial distribution networks. This unit is configured with 0.35 kV primary and 1 kV secondary and ONAN cooling.

Can you change the rating or voltage of this oil-immersed distribution transformer?

Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.

Which standard applies to this oil-immersed distribution transformer, and is it certified?

The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.

What cooling and protection are fitted?

Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.

What information should we send for a quotation?

The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.

Application

Rated Capacity

Voltage Class

Environment

Reviews

There are no reviews yet.

Be the first to review “8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer”

Your email address will not be published. Required fields are marked *

📋 Request a Quote

Request a Quote

Fill in your details and our engineers will contact you within 24 hours

Prefer to contact us directly?

Email: info@xsdfftransformer.com | Phone: +86 158 6789 7761 | WhatsApp: +852 2416 2620

Scroll to Top