The 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer is a three-phase power transformer for substation, heavy industrial and utility duty where capacity and network conditions are specified more closely than for standard distribution units. Ratings are configured per the technical parameters below and confirmed against your system data.
Cooling method, vector group, impedance and tap range are engineered against your load profile and network parameters. Each unit is routine-tested before dispatch, and engineering support is available from enquiry through to commissioning.
Technical Parameters & Ratings
| Rated Capacity | 8000 kVA |
|---|---|
| High Voltage | 35 kV |
| Low Voltage | 1 kV |
| Frequency | 50 Hz / 60 Hz |
| Phase | Three Phase |
| Cooling Method | ONAN / ONAF optional |
| Vector Group | YNd11 / Dyn11 / Yyn0 / customized |
| Tap Changer | Off-circuit tap changer / on-load tap changer optional |
| Tapping Range | ±2 x 2.5% / ±5% / customized |
| Winding Material | Copper / Aluminum |
| Core Material | CRGO silicon steel |
| Insulation Medium | Mineral insulating oil |
| Tank Type | Conservator tank / sealed tank optional |
| Accessories | Buchholz relay, oil level gauge, thermometer, pressure relief device, valves |
| Impedance Voltage | According to standard / customized |
| No-Load Loss | According to standard / customized |
| Load Loss | According to standard / customized |
| Standard | IEC / customized project specification |
| Installation | Outdoor |
| Application | Utility substations / industrial plants / infrastructure and regional power systems |
Technical Highlights
- This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.
Application Scenarios
- Solar power plants
- Wind farm collector and grid interface systems
- Photovoltaic station and inverter interconnection projects
- Battery energy storage systems (BESS)
- Renewable energy substations and export EPC projects
Key Features
- 8000 kVA rated capacity for renewable interconnection, step-up, or project-side power conversion
- Designed for solar, wind, PV, or energy-storage power system applications
- Configurable voltage ratio for inverter-side, collector-side, or grid-side connection
- Oil-immersed construction for dependable cooling in outdoor renewable projects
- Project-oriented accessory and monitoring options available
- Suitable for IEC-based renewable projects and export EPC supply
Optional Configurations
- Low-voltage side rating and voltage ratio
- Frequency: 50 Hz or 60 Hz
- Vector group and tapping range
- Copper or aluminum winding
- Cooling method, accessory package, and monitoring option
- Tank structure, coating system, and special environmental adaptation
- Color, nameplate language, and document package
- Ambient temperature, altitude, and installation condition adaptation
Frequently Asked Questions
Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?
It is built for utility, industrial and commercial distribution networks. This unit is configured with 0.35 kV primary and 1 kV secondary and ONAN cooling.
Can you change the rating or voltage of this oil-immersed distribution transformer?
Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.
Which standard applies to this oil-immersed distribution transformer, and is it certified?
The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.
What cooling and protection are fitted?
Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.
What information should we send for a quotation?
The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.
Typical Applications
The 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer is specified in projects such as:
- Substation step-up and step-down duty
- Heavy industrial process power supply
- Generator step-up for small plant and embedded generation
- Grid interconnection where impedances are specified
Manufacturing & Factory Testing
Transformer manufacturing at our works, with quality control checkpoints through production and complete routine testing before dispatch:
- Core cutting and winding with controlled process parameters
- Vacuum drying and oil filling (oil types) or epoxy casting (dry types)
- Routine tests: winding resistance, ratio and polarity, no-load and load loss, applied and induced voltage
- Type test certificates from accredited laboratories available on request
Technical Drawing

Delivery, Warranty & OEM Support
- Typical lead time: 30 days from order confirmation for standard ratings; custom configurations are confirmed at order stage
- Warranty: 2 years, with technical support available throughout the service life
- OEM / ODM supported: private labelling, nameplate language and document packages
- Seaworthy export packing; documentation set includes routine test reports, installation manuals and general arrangement drawings
Need a quotation for the 8000 kVA 1.0/35kV Three-Phase Renewable Power Transformer? Send your single line diagram and ratings to our sales team and our engineers will confirm the configuration, lead time and price.
Frequently Asked Questions
Where is a 8000 kVA Oil-Immersed Distribution Transformer normally installed?
It is built for utility, industrial and commercial distribution networks. This unit is configured with 0.35 kV primary and 1 kV secondary and ONAN cooling.
Can you change the rating or voltage of this oil-immersed distribution transformer?
Yes. Ratings are set from your project, not from a fixed catalogue. Send the single-line diagram and load list and we size the windings, tap range, cooling and protection to what the site actually needs. Vector group, frequency and terminal arrangement are confirmed on the drawing before anything is built.
Which standard applies to this oil-immersed distribution transformer, and is it certified?
The applicable standard and the clause set are agreed against your project specification before production starts. Where a project names IEC 60076 for the transformer or IEC 62271-202 for a prefabricated substation, we work to those clauses and ship the routine test report with the unit.
What cooling and protection are fitted?
Cooling is ONAN. Protection and monitoring are selected to the single-line diagram: winding and oil temperature indication, Buchholz relay or pressure relief where the design calls for it, and surge arresters on the terminals. Indoor or outdoor placement, enclosure rating and foundation details are fixed with your site conditions.
What information should we send for a quotation?
The single-line diagram, the load list, the system voltage and frequency, and the site conditions that affect the design – altitude, ambient temperature range, indoor or outdoor, enclosure rating. With that we come back with a drawing and a price. If you only have a rating in mind, send that and we will work the rest out with you.